Prior to installing the ridge vent a 1 inch wide strip of roof decking is cut out along both sides of the ridgeline to allow for air movement through the vent.
Proper roof ridge vent installation.
Before the ridge vent installation begins the crew installs pieces of peel and stick membrane to patch under the existing felt paper on the adjacent wall.
The first step is to check out this 60 second video and learn about the 300 1 rule the difference between intake and exhaust ventilation and why proper ventilation is so important to get right to help calculate your attic ventilation needs visit gaf ventilation calculator.
Your roof may have a ridge vent which is a low profile continuous roof air vent running along the peak of the roof.
How do you pick the right attic vent.
Vents evenly spaced underneath the roof provide intake.
This gives you 450 square inches of total exhaust.
Touch your ceiling on a warm sunny day.
To achieve a balanced system with cobra 4 1 21 m plastic ridge vents there must be an air intake system i e soffits fascia or undereave intake vents.
Then they lap the peel and stick existing felt and new housewrap over the step and kick out flashings so that any water hitting the wall is directed onto the roof instead of behind the flashing.
Several ridge vent installation tips are given in this video.
A ridge vent is a ventilation strip that is placed along the ridgeline of the home.
Tools you will need for roofing from amazon bostitch coil nailer https amzn to 2u1v8e2 shingle remover https amzn to 2fzu5wf roof snake https amzn to 2.
A hot ceiling tells you that the attic is acting like a solar oven raising your cooling bills and cooking.
Because the vent material will look different than the shingles some homeowners may choose to have their roofer shingle over the ridge vent once it s installed.
For ridge vent to function properly it must be the only exhaust vent for the vented attic space.
These vents are laid along the ridge of the roof and can come as a series of separate pieces or one long piece.
Or it may have gable vents which are louvered openings at the top of gables.
Multiply it by 18 square inches the net free air per foot of ridge.
It is important that air movement occurs and is not impeded by any framing members of the.
To calculate an example of exhaust and intake use 25 feet of roof ridge vent.
Position the aluminum ridge vent along the reference line.
One of the fundamental steps is to nail one side of the ridge vent before nailing the other sid.
Add any connectors and end caps that came with your ridge vent system to ensure the vent is watertight.